  1. Msha ground continuity testing - Electrician Talk

    Feb 8, 2014 · Anybody have experience with doing ground testing for msha? We are running into a problem when we measure the circuit ohms. We start out with a 500' spool of wire and have .7 ohms …

  2. Grounding motor frames. - Electrician Talk

    Apr 21, 2024 · I used to do Msha testing so am familiar. Vfd cables have a great ground internally though. We, the installer, are adding all these motor frame jumpers. I was told by fellow workers it’s …

  3. Pendant Receptacle Boxes - Electrician Talk

    Aug 3, 2023 · Interesting MSHA has no authority over the buildings here is the kicker not in the mine. That was OSHA. Ended up in HR again over that one. Fortunately the mine manager agreed with me …

  4. Ground rod resistance - Electrician Talk

    Sep 1, 2010 · How do you measure the resistance of a ground rod and what instrument do you use?

  5. Unmarked cab tire caple of running 65Amps?! | Electrician Talk

    Nov 10, 2010 · Okay. "MSHA" is Mine Safety and Health Administration "P" means that it meets the additional requirements of the state of Pennsylvania Bureau of Mines "159" means that it was …

  6. Service Conductors to multiple services - Electrician Talk

    Nov 27, 2024 · For insance MSHA says that any abandoned wiring must be REMOVED. I can't tell you how many industrial plants or even residential areas where you see old dangling wiring hanging out …

  7. Electrical panel dead front - Electrician Talk

    Sep 13, 2024 · I need a little help with defining a dead front for an electrical panel. The code states to protect from all exposed live parts. Does this include wires and the sides of the breakers? With …

  8. Polaris VS Lugs - Electrician Talk

    Jan 21, 2022 · Of those the true mining cables seem to work the best or SOOW because the jacket is molded to it so that it tends to move with the wiring and you get no rubbing. At one mine around here …

  9. NEC 422.5 QUESTION - Electrician Talk

    Nov 3, 2022 · NEC 422.5 (A), (2) shows that GFI protection is required for drinking water coolers "and bottle fill stations". One inspector is interpreting this to cover drinking water dispensers which use …

  10. Tray cable as a bus drop - Electrician Talk

    Jul 23, 2024 · In MSHA jurisdiction, SO cord is THE wiring method used for entire aggregate screening and crushing plants, and concrete plants built in aggregate mines. I’ve only seen it a few times, but …